Verification of Space Weather Forecasts issued by the Met Office Space Weather
M. A. Sharpe1, S. A. Murray2
1Met Office, UK. 2Trinity College Dublin, Ireland.
Key Points:
• An operational real time verification system has been developed for geomagnetic storm and solar flare forecasts. • Ranked (probability) skill score, ROC plots, and reliability diagram analyses are shown for a period between April 2015 and October 2016.
• Both geomagnetic storms and flares were generally over-forecast. • The skillful rolling prediction periods of 180 and 120 days were identified for geomagnetic and flare forecasts, respectively.
Abstract
The Met Office Space Weather Operations Centre was founded in 2014 and part of its remit is a daily Space Weather Technical Forecast to help the UK build resilience to space weather impacts; guidance includes four day geo-magnetic storm forecasts (GMSF) and X-ray flare forecasts (XRFF). It is crucial for forecasters, users, modelers and stakeholders to understand the strengths and weaknesses of these forecasts; therefore, it is important to verify against the most reliable truth data source available. The present study contains verification results for XRFFs using GOES-15 satellite data and GMSF using planetary K-index (Kp) values from the GFZ Helmholtz Centre. To assess the value of the verification results it is helpful to compare them against a reference forecast and the frequency of occurrence during a rolling prediction period is used for this purpose. Analysis of the rolling 12-month performance over a 19-month period suggests that both the XRFF and GMSF struggle to provide a better prediction than the reference. However, a relative operating characteristic and reliability analysis of the full 19- month period reveals that although the GMSF and XRFF possess discriminatory skill, events tend to be over-forecast.
1 Introduction
In recent decades there have been significant technological advances upon which governments, industries and organizations have become increasingly dependent. Many of these advances are vulnerable to space weather to the extent that security and/or safety could be severely compromised when significant events occur. After severe space weather was added to the UK’s National Risk Register of Civil Emergencies in 2011, the UK government sought to establish a 24/7 space weather forecasting centre and the Met Office Space Weather Operations Centre (MOSWOC) was officially opened on 8th October 2014. Part of MOSWOCs remit is to issue a daily Space Weather Technical Forecast (SWTF) to help affected UK industries and infrastructure build resilience to space weather events; issued at midnight with a midday update,
• Solar Radiation Storm Forecast; And
• high energy electron event forecast. Verification of these products is crucially important for forecasters, users, modelers and stakeholders because it facilitates an understanding of the strengths and weaknesses of each forecast product. Ideally verification should be performed in near-real time to enable instant
Forecaster Feedback Because This Enables:
a) necessary corrections to be made in a timely fashion; and b) operational forecasters to use the results to further develop their forecasting skills. As a member of the International Space Environment Service (http://www.spaceweather.org), the Met Office is helping to coordinate verification efforts with 1. NASA Community Coordinated Modelling Center on the implementation of the Flare Scoreboard (https://ccmc.gsfc.nasa.gov/challenges/flare.php); a system to enable the automatic upload of flare predictions and provide immediate verification to inter- compare the forecasts from participating organisations; 2. the EU on the development project Flare Likelihood And Region Eruption foreCASTing (FLARECAST; http://www.flarecast.eu) to automatically forecast and verify X-ray flares.
Some initial MOSWOC flare forecast verification has been undertaken as part of the FLARECAST project (Murray et al, 2017), however the real-time operational verification system that has now been developed for use by the MOSWOC forecasters was not fully explored in this work. Operational verification of most SWTF products is planned and progress to date includes investigations into the skill of GMSFs, XRFFs and Earthbound-CME warnings; with near-real-time verification of the former two products already operational using the Warnings Verification System (WVS) (Sharpe, 2015) and the Area Forecast Verification System (AFVS) (Sharpe, 2013). The methodologies used to verify GMSFs and XRFFs are outlined in Section 2 and results for the period between April 2015 and October 2016 are presented in Section 3.
Section 4 contains brief conclusions and an outline of further work.
2.1 Geo-Magnetic Storm Forecasts
The GMSF is both probabilistic and multi-category; each category referring to a different geo- magnetic activity level, measured using the K index at 13 observing sites stationed across the globe, from which a planetary K value (Kp) is evaluated. GMS level: G1/G2. (Minor/Moderate) denote Kp values of 5-, 5o, 5+, 6-, 6o or 6+;
G3. (Strong) Denote Kp Values Of 7-, 7O Or 7+;
G4. (Severe) denote Kp values of 8-, 8o or 8+; and G5. (Extreme) denote Kp values of 9-, 9o or 9+. Additionally G0, denotes Kp values of 4+ or below.
Forecasters issue GMSFs by first analyzing images to identify CMEs and coronal holes and then using the Wang-Sheeley-Arge Enlil model (Edmonds, 2013) to identify high-speed solar wind streams and CMEs. However associated forecasts of GMSs are limited because values of the z– component of the sun's magnetic field are unknown (except as measured by the ACE/DSCOVR satellite). One further source of information is from an Autoregressive Integrated Moving Average model of Kp values; however, there is no model which accurately predicts Kp fluctuations. Consequently, forecasting is essentially a subjective process which continues to rely heavily upon the experience of operational forecasters.
Table 1 shows the GMSF within the 00Z issue of the SWTF on 1st October 2016.
1
1
1
1
Table 1. GMSF contained within the 00Z SWTF issued on 1st October 2016.
1. A Single Word Description Of The Gms Type;
2. the G-scale level associated with this type of GMS; 3. whether each type of GMS has been observed during the previous 24 h period; 4-7. forecast probabilities for the likelihood that each type of GMS will occur during four consecutive days into the future.
During day 1 (Table 1 column 4) the predicted probability of a GMS level: ≥ G1 was 55%, ≥G3 was 5%, ≥ G4 was 1% and ≥ G5 was 1%. However, the minimum forecast probability is stipulated at 1%; therefore in this analysis a forecast value of 1% is interpreted as 0%.
The probabilities in Table 1 refer to the chance that the GMS level will be reached or exceeded at least once during the 24 h period. Therefore, column 4 forecasts that the probability associated
G3. Is 5% - 0% = 5%;
G4. and G5. is 0%. GFZ Helmholtz Centre Potsdam Kp values are used as the truth data source for GMSF verification; however, these values have a one-month latency period which makes them unsuitable for near-real-time verification. Consequently, estimated Kp values from the Space Weather Prediction Center (SWPC) are used to provide valuable feedback to MOSWOC forecasters. During the first ten months of 2016, SWPC and GFZ Kp values differed on 81 days.
The verification metric most commonly associated with multi-category probabilistic forecasts is the Ranked Probability Score (𝑅𝑃𝑆) (Epstein, 1969 and Murphy, 1971). The RPS is defined by
+12
; (1) where in the present case 𝑃(𝐺+) is the forecast probability that the maximum GMS level to be observed during the 24h period is ≤ 𝐺+ (where 𝑛= 0, 1/2, 3, 4 or 5) and 𝑂(𝐺+) is 0 if the maximum observed level is < 𝐺+ and 1 otherwise. The 𝑅𝑃𝑆 (which ranges from 1 to a perfect score of 0) is calculated separately for every day of each forecast and a mean value (𝑅𝑃𝑆
<<<<<<) Is
obtained by simply averaging the 𝑅𝑃𝑆 values calculated for a large number of forecasts; 90% confidence intervals are produced using simple bootstrapping with replacement. The 𝑅𝑃𝑆 provides a very valuable approach to the problem of verifying multi-category probabilistic forecasts; however, a reference is required against which to benchmark the performance. Three common reference forecast choices are: random chance, persistence and climatology. Short-term climatology (subsequently referred to as a prediction-period) has been chosen for the reference in the present study and 𝑅𝑃𝑆=>? has been evaluated by replacing 𝑃(𝐺+) in Equation (1) with the frequency of occurrence of GMSs over a prediction period encompassing the most recent 180 days. 180 days was chosen following an investigation (outlined in Section 3) which revealed it to be an accurate predictor period for GMSs. The use of a reference forecast enables the Ranked
<<<<<<
<<<<<
Verification of the GMSF has been performed for each forecast range by the AFVS (Sharpe, 2013) using daily maximum values of Kp. The AFVS was originally designed to verify a range of forecast categories against a truth data distribution (representing the conditions throughout an area); however, when presented with a truth data source containing only a daily maximum it can also be used to verify a daily maximum forecast like the GMSF.
An alternative verification approach is to treat the GMSF as a probabilistic warning service, verifying the forecast probabilities associated with each GMS level separately. In practice however, only categories ≥ G1 may be evaluated, because the more severe levels occur so rarely that robust statistics cannot be obtained over the available time frame. In the present study the Warnings Verification System (WVS) (Sharpe, 2015) has been used to verify the GMSF as a service, using Relative Operating Characteristic (ROC) plots and reliability diagrams (Jolliffe and Stephenson, 2012). The WVS is a flexible system originally developed to verify terrestrial weather; this system allows the analysis of near-hits by way of flexing thresholds in terms of space, time, intensity and confidence. However, in the present study flexing has only been applied in terms of intensity so that Kp values of 4-, 4o and 4+ are each categorized as a ‘low- miss’ except when they occur during a warning when they are categorized as a ‘low-hit’. The only other possible flex appropriate to this analysis is time because: confidence flexing cannot be applied since there is only one definitive Kp value and spatial flexing cannot be applied since no near-Earth Kp values are available against which to assess the forecast.
2
2
2
2
Table 2. XRFF contained within the 00Z SWTF on 21st July 2016.
2.2 X-Ray Flare Forecasts
The second aspect of the SWTF considered in the present study is the X-ray Flare Forecast (XRFF); a sample of which is shown in Table 2. This forecast is similarly displayed to the GMSF shown in Table 1; from left to right, column(s):
1. Contains A Description Of The Type Of Xrf;
2. identifies the class associated with each type of flare; 3. identifies whether any XRFs have been observed during the previous 24 h period; 4-7. contain forecast probabilities that each type of XRF will occur during four consecutive days into the future.
Forecast probabilities for each active region are calculated using a Poisson-statistics technique (Gallagher et al, 2002) based on historical flare rates for forecaster-assigned McIntosh classifications (McIntosh, 1990). These active region probabilities are combined to give a full- disk forecast, i.e., the chance of a flare occurring somewhere on the solar disk in the next 24 hours. The resulting model probability can be edited by the MOSWOC forecaster using their expertise before being issued as the Day 1 forecast as shown in Table 2. The Day 2-4 forecasts are purely based on forecaster expertise. More details about the forecasting method can be found in Murray et al, 2017. The XRF classes below M-class are A-class, B-class and C-class; however, these types of flare are not included in the forecast. In the soft X-ray range, flares are classified as A-, B-, C-, M-, or X- class according to the peak flux measured near Earth by the GOES spacecraft over 1-8 Å (in Wm-2). Each class has a peak flux ten times greater than the preceding one, with X-class flares having a peak flux of order 10-4 Wm-2.” During each 24 h period of Table 2 an M-class flare is predicted to occur with a probability of 28% and an X-class flare with a probability of 2%.
There is a subtle, yet important difference between the values contained within Table 1 and Table 2; in the former the probabilities denote the chance of exceeding each level, whereas in the latter the probabilities indicate the chance that each class will be observed at least once during the 24 h period. Consequently, using 𝑃(𝑋) and 𝑃(𝑀) to denote the probabilities associated with X-class and M-class flares (as they appear in Table 2), it is theoretically possible for 𝑃(𝑋) to be greater than 𝑃(𝑀); whereas, 𝑃(𝐺5) > 𝑃(𝐺4) is impossible. Although the values in Table 2 denote the probabilities of observation (rather than exceedance), user interest will lie mainly in the maximum flux class to occur during each 24 h period; therefore, some manipulation of the values displayed in Table 2 is required. The following paragraph derives expressions for 𝑃(maximum flux is A,B or C-class), 𝑃(maximum flux is M-class) and 𝑃(maximum flux is X-class) from the probabilities that appear in Table 2 (denoted by 𝑃(M) and
𝑃(X)).
Evaluating the probability that the maximum flux is X-class is simple; because X is the
Maximum Possible Flux Class;
𝑃(maximum flux is X-class) = 𝑃(𝑋). (1) To calculate the probability that the maximum flux is M-class it is first necessary to observe that 𝑃(𝑀J) = 𝑃(minimum flux is X-class) + 𝑃(maximum flux is A, B or C-class) (2) where 𝑃(𝑀J) = 1 −P(M) is the probability that M-class will not occur. The XRF truth data source is long wave radiation observations reported by the Geo-Orbiting Earth Satellite (GOES- 15) which takes measurements every 60-seconds. X-class flares are very rare, for example Wheatland et al (2005) noted that out of 10,226 days from 1975 to 2003, M-class flares occurred on ~25% of those days whereas X-class events occurred on only ~4% of those days. Analysis for the present study reveals that X-class flares occurred on just over 2% of days between 2010 and 2015. Therefore, it is relatively safe to assume that the first term on the right hand side of Equation (2) is zero since it is virtually impossible for the minimum 60-second observation during a 24 h period to be X-class and consequently, 𝑃(maximum flux is A, B or C-class) = 1 − 𝑃(𝑀). (3) The final expression to obtain is 𝑃(maximum flux is M-class); since 𝑃(maximum flux is M-class) = 1 – 𝑃(maximum flux is not M-class)
It Follows That
𝑃(maximum flux is M-class) = 1 – (𝑃(𝑋) + 𝑃(Maximum flux is A, B or C-class))
Which, On Application Of Equation (3), Gives
𝑃(maximum flux is M-class) = 𝑃(𝑀) −𝑃(𝑋). (4) Equations (1), (3) and (4) are used to calculate maximum XRFF probabilities which are used by the AFVS to verify the skill using the RPS and the RPSS. For the latter, a reference forecast is necessary and (as with the GMSF) the frequency of XRF class activity during a rolling prediction period is used for this purpose. The analysis outlined in Section 3 suggest that a prediction period of 120 days is a suitable choice. The XRFF is also assessed by the WVS, verifying separately the forecast probabilities associated with M-class and X-class flares; in practice however, only M-class flares can be evaluated because during the trial period X-class flares occurred too rarely to facilitate the calculation of robust statistics. As was the case for GMS verification, only intensity flexing is applied, for which a low-hit threshold of 10-6Wm-2 (C-class) is used.
3 Results
Two 4-day SWTFs are issued each day; a main forecast is issued at 00Z and an update at 12Z. It is inappropriate to analyze the performance on day 1 by amalgamating the update with the main forecast because the day 1 component to this update is a 12 h (rather than a 24 h) forecast; therefore, only 00Z forecasts are considered in the present study.
3.1 Geo-Magnetic Storms
The RPS is used to assess the skill of MOSWOC forecasts; however, as discussed in Section 2, a reference forecast is required against which to benchmark the score by calculating the RPSS. Arguably the simplest (and most basic) choice is random chance since its production requires no prior knowledge or information. The skill associated with a forecast generated by random chance is usually low and consequently it does not predict events well. However, despite this random chance is used (implicitly) in a number of popular verification statistics such as the Equitable Threat Score and the Peirce and Heidke Skill Scores (Jolliffe and Stephenson, 2012). Persistence is another popular reference choice, again (no doubt) because it requires little prior knowledge or information; persistence forecasts usually predict that tomorrow will be the same as today. When events are rare or conditions are benign persistence can produce a very favorable score; however, it is a completely ineffective predictor of the onset of severe events. The third most popular choice for a reference forecast is climatology. This option is less common because it requires prior knowledge of the conditions over a long time frame; indeed, in meteorology it is common to calculate climatology over a 30 years period. This reference sets the probability of each forecast category to its climatological frequency of occurrence. Usually the climatological period is fixed in advance; for example, in meteorology it is common to compare the latest season against the distribution formed by accumulating each corresponding season over the 30- year period between 1981 and 2010 (National Climate Information Centre, 2017). The climatology of solar activity is dissimilar to meteorological climatology, so it is not valid to follow this methodology exactly; however, it is unclear which prediction period is most appropriate. Consequently, different period lengths (from 30 to 360 days) have been analyzed to obtain an accurate predictor. For each prediction period definitive GFZ data was used to calculate the frequency of occurrence of each GMS-level; however, GFZ Kp values are only available following a one-month (approximately) latency period (although SWPC produce real time estimates). The near-real time nature of GMS forecast verification precludes the use of truth data which is unavailable to the forecaster; therefore, a one-month latency period has been built into this analysis. Extensive checking confirmed that each prediction period length appeared to produce a similar 12-month rolling mean RPS value. Therefore, the minimum RPS value was calculated on only the first day of every month throughout the 16-year trial period. This method identified 180 days as the best performing prediction period length . Figure 1 (which uses definitive Kp-values from GFZ) displays the rolling 180-day frequency of occurrence of G0 (×), G1-2 (×), G3 (□) and G4 (□), and G5 (o) for this 16-year trial period (beginning January in 2001) which also includes the period of MOSWOC forecasts analyzed in the present study.
Figure 1 clearly reveals the extent to which G0 dominates, although there has been a decrease in its frequency in recent months; in the 180 day period to February 2016 G0 was the maximum GMS level to occur on only 78.4% of occasions, down from a previous high of 96.0% in the 180 day period to October 2014. During the period of SWTF analysis (April 2015 to October 2016) the maximum GMS level to occur in the 180 day prediction period was:
G5
Figure 1. Rolling 180-day frequency of occurrence of daily maximum GMS level.
Date (Month Year)
Figure 2. Rolling 12-monthly RPSS values (×) with 90% bootstrapped confidence intervals for each day of the GMSF. Days 1 to 4 are indicated by solid, long dashed, short dashed and dotted lines, respectively.
• G4 On Between 0% To 1.7% Of Days; And
• G5 was not observed. Although it is inappropriate to calculate the RPSS for individual forecasts, monthly or annual values are available via Equation (2) following an evaluation of 𝑅𝑃𝑆
<<<<<<=>? - The Latter
being calculated by substitution of the PDFs in Figure 1 for the forecast. Figure 2 displays rolling 12-monthly RPSS estimates (×) and 90% confidence intervals for each day of the GMSF throughout the April 2015 to October 2016 period of analysis. Each point in this figure is plotted against the final month of the 12-month period to which it corresponds, consequently March 2016 represents the period from April 2015 to March 2016, and October 2016 represents the period from November 2015 to October 2016. Although the RPSS is greatest on day 1 the majority of the confidence intervals associated with it cross the green no-skill line.
The lower tail of the intervals for October 2016 does not intersect with this line, implying evidence at the 90% level to indicate that the skill during this 12-month period is greater than that associated with a rolling 180-day prediction period of GMS activity. However, all remaining confidence intervals intersect the green line, indicating that there is currently no evidence to suggest that these forecast days are more skillful than a daily 180-day prediction period at identifying the correct maximum daily GMS level.
Figure 3 displays Relative Operating Characteristic (ROC) plots calculated using GMSFs issued between April 2015 and October 2016; these plots describe the skill associated with each day of the forecast at correctly discriminating the days on which Kp reached or exceeded 5- (G1). A ROC curve is simply a plot of the Hit Rate (the proportion of events that were forecast) against the False Alarm Rate (the proportion of non-events that were incorrectly forecast), both of which range between 0 and 1. The Hit Rate is positively orientated whereas the False Alarm Rate is negatively orientated. Each point on a ROC curve represents the value of these two statistics at a different probability level. If action is taken when the forecast probability of an event is low the Hit Rate will be relatively large because events are forecast more frequently; however, the False Alarm Rate will also be relatively large because many of these forecasts will be false alarms. As the action/no-action forecast probability threshold is increased the value of both statistics reduce (tending to zero when action is never taken) and a ROC curve is formed by drawing a line through all these points. The further this curve resides above and to the left of the leading diagonal the more skill the forecast has at correctly distinguishing events from non-events; however, a curve that resides close to the diagonal indicates that the forecast cannot distinguish events from non-events. Although the WVS assesses the performance of all levels identified in the GMSF, only G1/2 is considered in the present study because the performance statistics associated with more severe levels are insufficiently robust for detailed analysis due to their low base rates.
There are three ROC-curves in each sub-plot, the green curve represents standard (un-flexed) verification methodology, whereas the black lines apply flexing using low-hit and low-miss categories. All the points within each sub-plot of Figure 3 reside above the grey diagonal no-skill line, indicating that each day of the GMSF has skill at discriminating events of G1 or above. The black line formed by + points awards a hit to any warning during which the maximum Kp value is at least 4- but only registers a missed event when G1 is not forecast and the maximum Kp
Authors:
Peder EZ Larson 1, 2,* , Jenna ML Bernard1, James A Bankson 3, Nikolaj Bøgh 4, Robert A Bok1, Albert P. Chen 5, Charles H Cunningham 6,7, Jeremy Gordon1, Jan-Bernd Hövener 8, Christoffer Laustsen 4, Dirk Mayer 9,10, Mary A McLean11 12, Franz Schilling13, James Slater1, Jean-Luc Vanderheyden5, 14, Cornelius von Morze 15, Daniel B Vigneron1, 2, Duan Xu1, 2, and the HP 13C
94143, Usa.
Denmark. 5 GE Healthcare, Menlo Park, California, USA. 6 Physical Sciences, Sunnybrook Research Institute, Toronto, Ontario, Canada.
8 Section Biomedical Imaging, Molecular Imaging North Competence Center (MOIN CC), Medicine, Baltimore, MD, USA. Cambridge, United Kingdom.
14Jlvmi Consulting Llc, Dousman, Wi, Usa
#See Acknowledgements for a list of all HP 13C MRI Consensus Group Members This work was supported by the ISMRM Hyperpolarized Media MR Study Group, the ISMRM Hyperpolarization Methods & Equipment Study Group, and the Hyperpolarized MRI Technology Resource Center (NIH/NIBIB grant P41EB013598).
Abstract
MRI with hyperpolarized (HP) 13C agents, also known as HP 13C MRI, can measure processes such as localized metabolism that is altered in numerous cancers, liver, heart, kidney diseases, and more. It has been translated into human studies during the past 10 years, with recent rapid growth in studies largely based on increasing availability of hyperpolarized agent preparation methods suitable for use in humans. This paper aims to capture the current successful practices for HP MRI human studies with [1-13C]pyruvate - by far the most commonly used agent, which sits at a key metabolic junction in glycolysis. The paper is divided into four major topic areas: (1) HP 13C-pyruvate preparation, (2) MRI system setup and calibrations, (3) data acquisition and image reconstruction, and (4) data analysis and quantification. In each area, we identified the key components for a successful study, summarized both published studies and current practices, and discuss evidence gaps, strengths, and limitations. This paper is the output of the “HP 13C MRI Consensus Group” as well as the ISMRM Hyperpolarized Media MR and Hyperpolarized Methods & Equipment study groups. It further aims to provide a comprehensive reference for future consensus building as the field continues to advance human studies with this metabolic imaging modality.
Keywords: Hyperpolarized MRI, metabolic imaging, carbon-13, pyruvate, dissolution dynamic
Introduction
MRI with hyperpolarized 13C agents, also known as hyperpolarized (HP) 13C MRI, has shown great potential as a novel imaging modality, particularly for its ability to probe metabolic processes in real time. The first human studies with HP [1-13C]pyruvate were performed in 2011 in prostate cancer patients (1).
Since then, there have been over 60 papers published with imaging results of human subjects from 13 different sites, with applications including prostate cancer, brain tumors, breast cancer, kidney cancer, pancreatic cancer, metastatic disease, liver disease, ischemic heart disease, diabetes and cardiomyopathies. The vast majority of these studies used [1-13C]pyruvate (1–63), where [2-13C]pyruvate (64) and 13C-urea (56) have been demonstrated too.
As clinical HP 13C MRI advances, there is a growing need to build consensus for best practices, which are critical for comparing data across sites, performing multi-site trials,deploying methods to new sites, partnering with vendors, and potentially for obtaining broader regulatory approvals.
In March 2022, we initiated an effort to build consensus within the HP 13C MRI community with this opportunity in mind, and it was greeted with strong enthusiasm. The “HP 13C MRI Consensus Group”, containing over 55 members from 27 sites, identified the area of greatest need and opportunity for consensus building to be HP [1-13C]pyruvate human
●
Pyruvate is the most mature and widely used HP agent and has the most significant translational evidence emphasizing the potential clinical impact.
●
Clinical trials, particularly multi-site trials, have the strongest need for consensus methods to ensure that data can be combined across sites. This work is a Position Paper for which the goal is to describe current successful practices and study methods for HP [1-13C]pyruvate human studies along with justification to support those practices. This is divided into four major topic areas: (1) HP 13C-pyruvate preparation, (2) MRI system setup and calibrations, (3) data acquisition and image reconstruction, and (4) data analysis and quantification (Fig. 1). The current successful practices and study methods include a literature review of published peer-reviewed journal papers showing human HP [1-13C]pyruvate study data, up to September 2022 (1–63), as well as new unpublished information from surveys of HP 13C study sites. Based on this information, we also highlight the evidence gaps, strengths, and limitations of current practices which are summarized at the end of each section.
Figure 1: Illustration of the HP 13C MRI human study process, including the 4 major areas covered in this paper: Hyperpolarized 13C-pyruvate preparation, MRI system setup and calibration, Acquisition and Reconstruction, and Data Analysis and Quantification.
Figure 2: Anatomical targets of HP [1-13C]pyruvate MRI human studies published up to September 2022.
Hyperpolarized 13C-Pyruvate Preparation
This section covers the processes for creating the HP agent, 13C pyruvate, and will include many aspects and considerations that are needed to safely and effectively prepare doses for metabolic imaging studies in human subjects. These include material, personnel, equipment and facility, fluid path preparation, quality control, and release.
It is helpful to understand that the specifications of a dose of 13C pyruvate suitable for in vivo MR HP metabolic imaging were shaped in part by early preclinical studies performed by GE HealthCare summarized in Ref. (65). In short, the safety of the two novel drug components, 13C pyruvate and the electron paramagnetic agent (EPA) AH111501, were demonstrated in those studies. The more precise formulation of the dose suitable for human use was then determined from clinical studies (66) that included two Phase 1 clinical trials in young and elderly healthy volunteers without hyperpolarization of the 13C nuclei and another Phase 1/2a dose escalation and imaging feasibility study with HP 13C pyruvate in 31 prostate cancer patients at the With the exception of the first HP 13C imaging clinical trial, which utilized a prototype device in a cleanroom (1), all HP 13C studies performed in humans to date have utilized the SPINlab polarizer (manufactured by GE HealthCare). Consequently all doses of the HP 13C pyruvate delivered by SPINlab have been produced using the “SPINlab Pharmacy Kit” that serves as the container-closure system for the various drug components (13C pyruvic acid and EPA mixture, dissolution medium, and neutralization and dilution medium) during sample polarization, dissolution and quality control (QC) processes. Thus many aspects of the HP sample preparation considerations discussed below are related to the SPINlab instrument and the consumables designed to be used with it (67).
General Considerations
While more than 860 patients or healthy subjects having been injected with HP 13C pyruvate as of January 2022 without reports of any serious adverse events (68), HP 13C pyruvate injection remains an investigational MR contrast agent and can only be administered by those with Investigational New Drug (IND) exemption from the Food and Drug Administration (FDA) in the USA, a Clinical Trial Application (CTA) in Canada, approval from National Research Ethics Committee Services in the UK, or approval from the relevant local regulatory body. Thus, methods and processes involved to produce a dose should have patient safety as the first priority. Since utilizing dissolution dynamic nuclear polarization (dissolution-DNP) for human use is still a relatively new development, there are no existing published regulatory guidelines specifically for this method.
There are two major production styles that determine how various sites approach the agent preparation. In the US, the most common approach is to rely on a sterilizing filter (“Terminal Sterilization”) to ensure sterility of the final product, akin to PET tracer production, where a starting molecule with a radioisotope is processed using various other ingredients to make the final, desired and injectable contrast agent within a necessarily short amount of time (69). For these sites, sterilization of the components and accessories upstream of this filter are not required, although many of them were manufactured and tested following Good Manufacturing Practice (GMP) or Good Laboratory Practice (GLP) requirements. The filling process is usually performed under an ISO 5 laminar flow hood, but a clean room or an isolator is not required.
This approach is typically accompanied by testing the integrity of the sterilizing filter prior to release of the dose for injection. Typically, post release endotoxin and sterility tests are performed using an aliquot reserved from each released dose.
In the UK and EU, the most common approach is to more-closely follow sterile pharmaceutical compounding guidelines (70), where all components and ingredients are required to be sterile or manufactured under GMP guidelines and are assembled and filled within a clean room environment or an isolator system (“Sterile Preparation”). Typically a batch of Pharmacy Kits for HP 13C pyruvate injection are prepared together. The sterility of the final dose is also ensured by batch validation testing, in addition to the sterility of the ingredients and the sterile compounding process. The endotoxin and sterility testing are performed for the process validation but are not performed for each injected dose.
Some institutions fill and assemble the Pharmacy Kit required for a specific study on the same day or the day prior to polarization, dissolution, and patient administration, but others have also demonstrated the feasibility of preparing a batch of kits, keeping them in a -20ºC freezer and using them over a period of a few months.
Beyond the obvious requirements that the process and the facility has to ultimately produce a dose that is safe to inject into a human, regulatory authorities will also focus on the question “Are you in control of your processes?”. To be in control of your process requires an in-depth and broad understanding of all processes involved in pre, post, and during the production process.
Personnel
It is typical and may be required to have licensed personnel involved in the production process depending on local regulations.Typically a pharmacist, radiopharmacist or other similarly qualified person (QP), in charge of the facility where the Pharmacy Kit filling and preparation is taking place, is responsible for the overall process and the release of the injectable dose.
Qualified cleanroom technicians are often involved in the Pharmacy Kit filling under the supervision of the pharmacist or QP. As is required for pharmaceutical compounding or PET tracer production, training requirements and training records for all personnel need to be maintained and available for audit by the FDA or equivalent.
Equipment And Facility
The facility and all equipment need to have standard operating procedures (SOPs) that describe how equipment is used, maintained, and calibrated to comply with relevant legislation. Currently, almost all the filling of the Pharmacy Kit takes place within a compounding laminar flow hood or isolator (typically ISO 5). At some sites, the filling is conducted within a cleanroom, while at others, it is conducted in a dedicated non-cleanroom space, reflecting differences in cleanroom approach and specifications between regulators worldwide (71). Some equipment or facilities, such as the compounding hood or cleanroom, may require external certified laboratories for testing.
Material Handling
Material handling guidelines (69,70) require SOPs detailing a system to track all of the materials involved in the HP production process for a particular patient dose, similar to current good manufacturing practice (cGMP) requirements for material handling for drug compounding. This includes acceptance standards, storage conditions, amount used in the patient dose for each ingredient and materials used in the assembly of the fluid path and Pharmacy Kit. Currently some users choose to open and inspect and sometimes modify the Pharmacy Kits upon arrival, but some users keep them in the sealed packaging until they are required for dose preparation.
Pharmacy Kit Filling And Assembling
As required by an IND or its equivalent, the preparation of the doses of HP 13C agent are detailed in the Chemistry, Manufacturing, and Control (CMC) section of an applicable regulatory submission; an example of this has been made available (72). It describes the processes of filling the Pharmacy Kit with the different components that make up the final drug product, and of assembling the final kit for either storage or immediate use in the polarizer. Special attention should be given to the laser welding process in order to satisfy installation qualification (IQ) and operational qualification (OQ). Typically, the final developed process is validated by process qualification (PQ) runs, during which 3 or more Pharmacy Kits are filled and used and the final HP 13C products are tested for endotoxin and sterility and to confirm that they meet the dose specifications for injections (usually including pyruvate concentration, residual EPA concentration, pH, liquid state polarization level and dose temperature). The data from 3 consecutive PQ runs are submitted as part of the IND submission (or its equivalent), and are often also reviewed by the Institutional Review Board (IRB) where the studies are conducted.
Quality Control And Dose Release
The quality control (QC) and dose release can be separated into two aspects: one is the QC and release of the filled Pharmacy Kit, and second is the QC and release of the HP 13C agent for injection, after polarization and dissolution. For institutions filling a batch of kits and storing them to use over a period of time, typically the batch can be released based on initial validation, environmental monitoring data from the day of kit production, and if filters are used during preparation of any of the components, filter integrity testing. But in some cases one or more kits are used for validation before the batch of kits are released for future use. For institutions that fill only the kits required for specific studies shortly before the experiment, the filled kits often do not go through separate release tests before they are used.
The quality control of the HP 13C pyruvate solution post dissolution is primarily performed to ensure that the agent meets the dose specifications (Table 1) before it is administered to the subject. These specifications target both safety (pH, residual EPA, temperature) and efficacy (pyruvate concentration, polarization, volume). Typically, the pyruvate concentration, residual EPA concentration, pH, dose temperature, dose volume, and liquid state polarization are measured by the QC accessory associated with the SPINlab polarizer. Some users perform a secondary measurement for one of the parameters, such as pH, using a different instrument or pH paper. For sites that do not go through a separate release testing process for batch filled kits, the integrity of the sterilization assurance filter, a part of the Pharmacy Kit, is typically tested as a part of the dose release. It is also common for these users to preserve an aliquot of the final HP 13C pyruvate solution for post-release endotoxin and sterility testing. This testing cannot be completed fast enough to test an individual dose prior to injection, but this is why other processes such as PQ runs and validation testing are done to minimize the chance a subject could be injected with a contaminated dose.
The Final Dose Release And Injection
should be done under the supervision of a licensed professional, based on local regulations.
Some Key Challenges
Many of the challenges associated with HP 13C pyruvate preparation can be attributed to the conditions required for the dissolution-DNP method of high magnetic field (~3-7 T) and very low temperature (~1 K) during polarization, with pressurized and superheated water necessary for the rapid dissolution event. These extreme conditions are quite challenging for the design of the container-closure and fluid path system. In particular, the cryogenic temperature in the polarizer requires special attention to any moisture or ambient (moist) air introduced into that portion of the fluid path, which can form an ice block at ~1 K. This ice can lead to flow restriction during the dissolution event and reduce the strength of the laser welded bond between the cryovial and its cap. This can ultimately produce failures in the dissolution step, including variations in final pyruvate concentration and pH that may fail to meet QC release criteria as well as fluid path ruptures that provide no available dose and result in polarizer down-time.
The polarization of the HP 13C pyruvate sample decays quickly over the span of a few minutes after dissolution, and thus the process of dissolution, QC for release, and injection should be completed as fast as possible to preserve the high polarization level achieved. Any delays in the preparation process, such as transportation time or equipment malfunction, can significantly reduce the final polarization and result in lower quality imaging data.
Current Practices
A summary of data collected from all sites performing clinical trials with HP 13C-pyruvate is shown in Fig. 3 and Table 1, including the specification of the final dose and how the quality control and release of the final dose are performed. There is a split in the Production Style, described in the General Considerations section above, with 8/13 sites using Sterile Preparation versus 5/13 using Terminal Sterilization. While many of the dose specifications show notable differences in acceptable ranges, all of these variations listed in tables have been successfully and safely been used to perform HP 13C pyruvate studies in humans. Their differences depend on the institutions’ preferences, resources and their particular regulatory situation. There is high similarity in pyruvate ranges, temperature ranges, EPA limits, and volume limits. There is modest variability in pH ranges and large variability in the endotoxin test limit. There is a 3-fold difference in acceptable polarization levels, which are measured to ensure a futile dose is not injected since the polarization is directly proportional to SNR. This reflects the decision by several sites to believe that useful data can be still be obtained with suboptimal polarizations.
Figure 3: Hyperpolarized agent preparation methods reported by sites currently performing HP
In House
Table 1: HP 13C-pyruvate preparation parameters, methods, and dose specifications used for quality control testing and release as well as validation. These were obtained from a survey of all sites performing clinical trials with HP [1-13C]pyruvate. The parameters used for product release are noted in bold text, otherwise these parameters are measured for batch validation or other QC measurements. The endotoxin and sterility testing are performed during process validation of the batch and/or post-injection, and largely depends on the agent production approach.
Summary
The overall safety record of HP 13C-pyruvate has been very strong, and the SPINlab hyperpolarizer has proven to provide high polarizations at human sized doses while meeting numerous QC and release criteria. A weakness remains the failure modes of the SPINlab Phamacy Kits (e.g. ice blocks, path ruptures), which are placed under extreme requirements particularly during dissolution. The preparation process still requires a high degree of expertise.
Therefore, there is a significant need to improve the reliability, robustness, and ease of operation for generating HP 13C-pyruvate doses for human studies. Furthermore, there is a divide between manufacturing and sterile compounding style preparation as well as other site-specific practices, resulting in variations in SOPs and justification required to relevant regulatory bodies. There have also been no comparisons between these approaches. It is also unclear what release criteria and QC parameters are truly required to ensure patient safety.
However, all of the reported methods are acceptable and approved by the appropriate regulatory authorities, and have led to the rapid expansion of successful human studies in recent years.
Mri System Setup And Calibrations
This section covers the MRI system setup, including the imaging system, RF coils, phantoms, and prescan calibration methods.
Imaging System
The main prerequisite for a given MRI scanner to be capable of supporting studies with HP 13C is its “broadband” capability to transmit and receive radiofrequency (RF) signal at the frequency of 13C, which is around 4 times lower than 1H. This does not come as a default on clinical MR devices. The transmit power of the broadband amplifier should also be sufficient to support the intended flip angle and RF pulse shape with the employed transmission RF coil(s) for 13C. Most studies to date use relatively low flip angles (< 90 degrees) for HP 13C in order to preserve polarization for time-resolved imaging. The capability to receive 13C signal on multiple channels is also desirable to increase SNR, as discussed further in the “RF coils” section.
The choice of magnetic field strength is primarily dependent on the metabolites’ frequency separation due to chemical shift dispersion and 1H imaging. High field strengths do not enhance hyperpolarized 13C signal as they do for 1H because the signal strength in a HP experiment relies on manipulating the population of quantum energy states outside of the MRI scanner.
However, the injected HP 13C-pyruvate and its metabolic products have greater frequency separation at higher fields, and it may thus be easier to separate and quantify these resonances at higher fields. This comes at the cost of a reduction in the achievable T2* and often reduced T1. As the initial polarization is independent of the imaging field strength it has been proposed that the increased T2* at 1.5T can potentially be exploited to increase SNR by adapting the acquisition bandwidth or reduce off-resonance imaging effects in cases when the decay of the transverse magnetization is dominated by T2* (73). In practice, 3T has been used in all published human 13C-pyruvate studies surveyed (Supporting Table S1), and comprises the majority of scanners currently in use for human studies (Table 3). A field strength of 3T is well-suited for 1H MRI anatomical reference and correlative imaging.
Stronger and more rapidly slewing magnetic field gradients support more rapid spatial encoding, particularly for metabolite-specific single-shot imaging using echo-planar imaging (EPI) or spiral imaging (See “Acquisition and Reconstruction”). Although the spatial resolution acquired for HP 13C imaging is typically much coarser than for 1H MRI, the factor of ~4 in gyromagnetic ratio leads to the same reduction factor in performance of the gradient system, so 13C experiments are potentially more limited by gradient hardware performance. To date, all human studies have used the commercially-available integrated gradient systems provided in clinical MRI scanners.
Optimization of scanner design has understandably focused on minimization of artifacts in 1H MRI, where devices such as room lights, the gradient amplifiers, and the motors driving the patient bed are checked to ensure that they do not produce RF interference at the 1H frequency, but artifacts may arise at other frequencies. Eddy current compensation is also not always appropriately adjusted for nuclei at other frequencies (74). In order to optimize for 13C, many sites have performed checks on phantoms for RF interference, gradient artifacts, and eddy currents (74), including the use of post-hoc gradient impulse response function characterisation and correction, and some vendors have fixed these issues as well.
Rf Coils
For HP 13C imaging studies in humans, RF coils for both 1H and 13C nuclei are needed, with 1H MRI providing an anatomical reference for registration and optional additional multiparametric MRI readouts. At the Larmor frequency of 13C nuclei, the relative contributions from coil noise compared to sample noise increase compared to 1H (73,75), although sample noise still is likely the dominant contributor for human-sized coils at 32.1MHz - the resonance frequency of 13C nuclei at 3T.
The key requirement for human 13C-pyruvate RF coils are that the coil geometry and sensitive volume must cover the volume of interest in the subject. Table 2 and Figure 4 shows coil configurations that have been used and optimized for applications in different anatomic regions.
Volume resonators are most commonly used for transmit, as they surround the subject to
Provide B1 Transmit Across The Fov (B1
+). While 1H relies on a large birdcage (“body”) coil built into the scanner, 13C transmit coils must be placed inside the bore. This takes up valuable space within the magnet, and also has led to the use of designs with relatively inhomogeneous
B1
+. Many human studies have used Helmholz pair resonators for transmit, including the “clamshell coil”, which has a notably inhomogeneous B1
+ Profile But Has Been Used Because Of
relatively easy integration into the scanner bore. B1
+ Variation Results In Variations In The Flip
angles that control the use of the hyperpolarized magnetization and creates errors in common HP metrics (9,76). The exception are head coils, where birdcage designs with highly
Homogeneous B1
+ can be placed around the head while easily fitting inside the bore. As with 1H MRI, higher SNR can typically be achieved by smaller receive coil elements, such as surface coils or phased arrays, and the majority of 13C receive coils used have layouts similar to 1H phased arrays.
RF coil quality control is important to ensure proper functioning of the coils to provide consistent imaging quality, especially with limited natural abundance 13C signal in vivo. It typically involves 1) a physical integrity check of the coil cables and connectors and 2) phantom SNR tests to check the coil’s performance and to monitor it over time (see Phantoms below). An useful reference for RF coil quality control is outlined in the MRI accreditation program of the American College of Radiology (77) and can be adapted for 13C coils.
Notably, configurations for brain and prostate studies used dual-tuned 1H/13C coil designs, which greatly simplify workflow and registration of 1H and 13C images, as no switching of coils is needed.
(1)
Table 2: RF coil configurations reported for human HP [1-13C]pyruvate studies.
Tx = Transmit
coil, RX = receive coil. The commonly used “clamshell” TX coil is a Helmholz pair design. For 1H RF configurations, all used the Body coil for TX unless otherwise noted, and “repositioned” indicates the 13C coil was removed for 1H imaging. One representative reference is listed for each configuration. The RF coil configurations reported in the reviewed papers are shown in Supporting Table S1.
Figure 4: Examples of RF coil configurations used for human HP [1-13C]pyruvate brain studies. (A,B) 13C Clamshell TX (Helmholz pair) and 2× 4-channel paddle RX arrays. (C) 13C Birdcage volume TX and 32-channel RX array (RX array slides into TX coil). (D) 13C Birdcage volume TX and 24-channel RX array, combined with a 1H 8-channel RX array. Image reproduced with permission from Ref (16).
Phantoms
Since hyperpolarized magnetization is non-renewable, phantoms containing 13C nuclei are important to: 1) test the multi-nuclear capabilities of the imaging system, including all parts of the signal excitation and receive chain; 2) perform calibration measurements before a scan with hyperpolarized nuclei; and 3) perform necessary pre-scan adjustments (see “Prescan Calibration” section). The phantoms currently in use are listed in Table 3. Their composition must provide sufficient 13C signal, with additional considerations of conductivity, stability, chemical shift(s) present, potential for dynamic imaging, and cost. The phantom geometries are typically either compact, in order to be used alongside the subject during a HP scan, or large enough to mimic the inner volume of a RF coil for system testing.
One popular compact design contains enriched 13C-urea at high concentration, typically 8 M, which provides a single resonance, placed inside a small container ~1 mL. The most common recipe mixes 13C-urea in a 90% water/10% glycerol solution, with glycerol used to increase the urea solubility and doping with a Gd-based contrast agent to shorten T1 which increases the potential SNR per unit time. For example, when Dotarem is added at a 3:1000 volume ratio the 13C-urea T1 is around 500 ms and T2 is around 100 ms. However, when testing pulse sequences influenced by T1 and T2, doping should be used carefully. This phantom is suitable for frequency calibration, transmit gain calibration, sequence testing, and as a fiducial marker when placed next to a patient. However, enriched 13C-urea has a relatively high cost compared to natural abundance compounds.
For larger volumes (>100 ml), the phantoms most often used contain undiluted ethylene glycol, glycerol, or dimethyl silicone. These compounds have sufficiently high carbon concentrations to provide sufficient 13C signal even with the 1.1% natural abundance of 13C. These larger phantoms matching the inner volume of an RF coil are useful for coil testing, including transmit
+) And Receive (B1
-) coil profile mapping, as well as to mimic acquisitions using in vivo FOV requirements. In this case, size and conductivity should match the expected subject size in order to mimic coil loading and get a realistic estimation of B1+. Large-volume natural abundance urea phantoms have also been used by some sites, but suffer from higher conductivity compared to biological tissues. Typically, it is easier to increase the conductivity and hence coil loading of the non-conductive phantom by adding NaCl to match physiological loading (16,78).
Dynamic phantoms that aim to mimic metabolite kinetics have also been developed (79–81), and have the potential to more closely mimic the HP experiment, but so far these are not widely used.
Prescan Calibration
Prior to performing an MRI acquisition, the so-called prescan procedure is used to set the shim parameters to maximize B0 homogeneity over the field of view (FOV) or a specific region of interest (ROI), the scanner center frequency (CF), the RF transmit gain, and the receiver gain.
While this calibration procedure is usually automated for 1H, the lack of sufficient natural abundance 13C signal prevents use of automated methods. (Although natural abundance 13C lipid signal has been detected, there are so far no reports on using this signal for prescan.) Table 3 shows current practices across sites.
Maximizing B0 homogeneity is independent of the nucleus and is therefore performed prior to 13C imaging using the 1H water signal and existing shimming tools, such as by a standard automated process (“Auto Shimming”) or using high order shimming routines. Similarly, the 13C CF can be calculated from the 1H CF using a predetermined scaling factor that depends on the target chemical shift (82). Another common approach used is to have a small, high-concentration 13C phantom, e.g. 8M 13C-urea, integrated in the RF coil or placed next to the scan subject (1). The reference frequency can also be based on real-time measurements after the HP injection but prior to imaging (83). Both the CF and B0 shimming are critical when using spectrally-selective RF pulses, as inmetabolite-specific imaging methods, where the desired excitation bandwidths are typically very narrow and frequency offsets can lead to a failure mode that is only apparent after injection.
The calibration of the RF transmit power is typically performed on a small, high-concentration 13C phantom placed near the region of interest during the scan or on a large 13C phantom of similar size and coil loading as the subject, prior to the subject scan. Reference power is often done by sweeping the power in a pulse-acquire sequence (53,62), or the Bloch-Siegert method (52,84). When using a small phantom, the location of the phantom, B1
+ Inhomogeneity As Well
as any shielding effects, e.g., when the phantom is integrated into a coil (1), may degrade the accuracy. Other methods include real-time Bloch-Siegert method measurements after the HP injection (83), and using the stronger natural abundance 23Na signal that is close enough to the 13C resonance frequency to be detected by 13C coils (82).
The receiver gain is predetermined, either systematically based on independent phantom measurements and assuming the dose and polarization of the HP compound is known prior to injection, or based on past HP imaging studies.
Power [Kw]
Phantom(s) - during study Phantom(s) - before study 13C Frequency
8
13C-bicarbonate doped with dimethyl silicone, various
Maximum Values
Table 3: Summary of the imaging systems, phantoms, and prescan procedures used at sites currently performing HP 13C-pyruvate human studies. These were obtained from a survey of all sites performing clinical trials with HP [1-13C]pyruvate. *Previously performed studies with a Siemens 3T Tim Trio. The imaging systems, phantoms, and prescan procedures reported in the reviewed papers are shown in Supporting Table S1.
Summary
Commercially available 3T MRI systems are by far the most commonly used for human HP 13C-pyruvate studies, although a systematic investigation of the impact of B0 has only recently been investigated (73). The multi-nuclear RF transmit and receive chain has proven sufficient for current acquisition strategies, although many sites have observed artifacts due to RF interference, gradient interference, and residual eddy currents when operating at the 13C frequency. A variety of 13C RF coils, tailored for numerous anatomical targets, have been successfully demonstrated, with the main limitation that most transmit coils take up a lot of additional space inside the bore and provide relatively inhomogeneous B1
+ Profiles. The
phantoms used have converged into generally 2 categories - small phantoms containing 13C-enriched compounds that can be used during the study and human-sized phantoms containing compounds with high carbon concentrations but without 13C enrichment that are used to test and calibrate the coils. There are no standardized compositions or geometry, and dynamic phantoms that recapitulate in vivo kinetics would be desirable but are still an emerging area. Prescan calibration procedures were not well defined in most publications, so we surveyed individual sites to determine current practices. Calibration procedures for the B0 field (13C CF and shimming) for most sites take advantage of 1H signal and methods, while methods
For Calibration Of B1
+ is more variable across sites, likely a reflection of remaining challenges in how to perform this calibration. Standardization of both phantoms and calibration procedures would synergistically improve the robustness and reproducibility of HP 13C studies.
Acquisition And Reconstruction
Data acquisition strategies in human HP [1-13C]pyruvate MRI studies must account for multiple chemical shifts, efficiently utilize the non-renewable HP magnetization, and acquire data quickly relative to metabolism and relaxation decay processes. These studies require spectral encoding to separate metabolites, necessitating pulse sequences that efficiently encode up to 5D data (3 spatial + 1 spectral + 1 temporal dimension). RF pulses must efficiently sample without immediately saturating the non-renewable HP magnetization, and sequences must acquire data quickly and be robust to both experimental and physiologic variation (e.g. B1
+ Inhomogeneity,
variation in perfusion) to ensure reproducibility and minimize scan-to-scan variability. This section covers current successful practices for data acquisition in human [1-13C]pyruvate studies, and accompanying 1H imaging, from different anatomic regions, including scan parameters and image reconstruction.
Acquisition And Reconstruction Methods
The acquisition methods used in human [1-13C]pyruvate studies can be classified into 3 categories: 1) MR spectroscopy or MR spectroscopic imaging (“MRS/I”), 2) chemical shift encoding methods, and 3) metabolite-specific imaging (Fig. 5).
Mrs/I Methods Specifically
resolve a spectrum that can be analyzed to extract expected as well as unexpected resonances, making this approach very robust. It was used in many initial studies (1).
Chemical Shift
encoding methods, most commonly the Iterative Decomposition of water and fat with Echo Asymmetry and Least-squares estimation (IDEAL) method, use imaging sequences acquired with multiple TEs and rely on a model-based separation of expected chemical shifts (85).
Metabolite-specific imaging methods use specialized RF pulses that are spatially and spectrally selective to excite individual metabolites which are then typically imaged with fast k-space trajectories such as echo planar imaging (EPI) or spirals (86).
Their Application To Different
organ systems is described below. The image reconstruction methods used in human [1-13C]pyruvate studies have typically been conventional methods (e.g. FFT, non-uniform FFT, or equivalent). The incorporation of accelerated imaging and advanced reconstruction methods including parallel imaging (4,57,87) and compressed sensing (7) has also been applied in human studies for improved spatial resolution, temporal resolution and coverage, but have the potential for additional artifacts as well as SNR losses due to ill-conditioning of the reconstruction (e.g. g-factor).
The Majority Of
published studies do not use accelerated imaging indicating the resolution and coverage achievable without acceleration is currently adequate for successful data collection. Performing coil combination, even with fully sampled data has also been shown to have specific challenges for HP human images: using naive sum-of-squares methods suffer from high noise amplification in the relatively low SNR regime of HP [1-13C]pyruvate (compared to 1H), motivating several HP 13C-specific methods that include data-driven coil sensitivity estimation which have shown obvious improvements over sum-of-squares (11).
More recently denoising techniques have been applied as post-processing of human HP data(41,42,44). The techniques applied are based on spatial-temporal singular value decomposition for unsupervised estimation of signal and noise components. They have shown improvements in apparent SNR in the brain and liver, while care must be taken to choose parameters such as the rank threshold to avoid oversmoothing and overfitting to the estimated signal components.
Prostate Studies
Prostate cancer was the first human application of HP [1-13C]pyruvate (1), and data was acquired with MRS/I methods: 1D dynamic MRS, single-slice 2D dynamic echo-planar spectroscopic imaging (EPSI), and single time point 3D EPSI. Advances in imaging strategies led to the development and application of new acquisition schemes, including undersampled 3D EPSI with compressed-sensing (7), model-based chemical shift encoding methods that use a priori information (47,59), and metabolite-specific EPI (10), all of which can provide volumetric whole-organ coverage and dynamic acquisitions.
The pyruvate bolus arrival in the prostate can vary by ± 10 s between patients, necessitating dynamic imaging to reliably and consistently capture the pyruvate bolus (18). For this reason, all currently ongoing studies acquire dynamic data. While MRS/I, chemical shift encoding, and metabolite-specific imaging can all achieve dynamic imaging, chemical shift encoding and metabolite-specific imaging provide greater dynamic and volumetric coverage (85). For scan prescriptions, the FOV is designed to provide full prostate coverage and typically to match the orientation of the anatomic imaging used for registration. Flip angles used in current studies are constant through time, as quantification with a variable-through-time flip scheme is highly sensitive to bolus timing (8) and errors in the RF transmit (B1 +) field (76).
Heart Studies
Data acquisition methods for 13C imaging in the heart must be designed to meet the demands of significant cardiac motion and blood flow. To cope with the periodic cardiac motion, most human heart studies to date used gating to the diastolic window, the longest cardiac cycle interval, which has reduced motion (2,22,28,30,35,36,38,45,52). The duration of the diastolic window limits the available data sampling time, making cardiac acquisitions the most time-constrained of the HP 13C MRI applications. The most common acquisition approach is metabolite-specific imaging with spiral k-space trajectories (2). Their single-shot imaging capability makes these methods particularly robust to motion effects. Furthermore, spiral k-space trajectories provide rapid k-space coverage and relatively benign flow and motion artifacts. The majority of studies have used 2D multi-slice acquisitions, but 3D encoding has also been used successfully (35).
Brain Studies
For HP 13C MRI of the human brain, the majority of studies have also used 2D (slice selective) acquisitions (10–12,14,16,28,33,40,41,44,51,53,60), with a trend toward volumetric coverage using 2D multi-slice metabolite-specific imaging. 3D metabolite-specific imaging of the whole brain, with phase encoding of the slice direction (34,57), has been shown to provide similar SNR efficiency (88) compared with multislice imaging. A number of studies have employed MRS/I (5,6,29,31–33,50,55) resulting in a spectrum from each voxel, which has the advantage of not requiring a priori information about which peaks to encode. This was important in early brain studies when it was not known which peaks would be detectable. Chemical shift encoding, using a set of images with different echo times and an iterative reconstruction of the individual resonances (i.e. the IDEAL approach (85)), has also been used (12,49,54), with the drawback that coverage in the slice direction was limited due to the time required to acquire multiple echo time images.
Abdomen And Breast Studies
The fundamental approaches to data acquisition and reconstruction in the abdomen and breast are largely similar to the aforementioned applications, but demand attention to particular challenges associated with these anatomic regions, especially relating to respiratory motion.
Although it has been shown that a basic 2D MRSI approach based on phase encoding and FID readout can be successfully applied for HP 13C imaging in breast (15) and kidney (13), major advantages in terms of spatiotemporal resolution and coverage have been realized using tailored approaches based on metabolite-specific imaging (43,62) and chemical shift encoding (43), which have facilitated multi-slice or 3D dynamic acquisitions over large FOVs in the abdomen (4,37,46).
The significant respiratory motion encountered in these regions can directly blur 13C images, and has further favored these rapid acquisition strategies. Motion also degrades B0 homogeneity, which can shift frequency-selective excitation profiles and introduce artifacts into rapid imaging readouts. This makes accurate determination of the acquisition center frequency and shimming essential in these regions which often cover large FOVs. (See “Prescan Calibration” section for more information). In some studies, breath-holding was used to minimize motion effects and enforce frame-to-frame data consistency (42). A pragmatic and reasonably effective approach for dealing with respiratory motion during 13C data acquisition is an initial breath-hold (as long as can be tolerated), followed by free-breathing (46,62).
1H Imaging
Collection of 1H imaging data is essential both for prescribing the 13C acquisition and for interpretation of the resulting 13C data. Multi-planar 1H scouts are acquired prior to 13C acquisition to enable graphical prescription of the 13C imaging region. All human HP 13C-pyruvate imaging studies acquire conventional MRI scans (e.g. T1- and T2-weighted volumes) for anatomic reference, aiming to cover at least the full 13C FOV. Acquiring these anatomic scans as close as possible to the time of 13C imaging (immediately before or after) minimizes potential misregistration between the data sets. Depending on the application, other advanced 1H sequences are also acquired (e.g. diffusion-weighted imaging for cancer imaging).
When contrast-enhanced data is acquired, it is done after 13C imaging, as paramagnetic contrast agents will accelerate 13C relaxation.
Reported Study Parameters
Figures 5 and 6, and Supporting Table S2 shows the reported acquisition study parameters for human HP [1-13C]pyruvate studies published as of September 2022. Figure 5 shows a mixture of MRS/I, metabolite-specific imaging, and chemical shift encoding methods have been successfully used, where spectroscopy-based methods have become less prevalent in recent studies. Figure 6 shows the acquisition timing, including the important start time and interval/temporal resolution, is quite variable across studies.
Figure 5: Acquisition methods used in published HP [1-13C]pyruvate human studies published up to September 2022, classified into: MR spectroscopy and spectroscopy imaging (MRS/I); chemical shift encoding methods, such as IDEAL, that use multiple TEs and model-based reconstructions; and metabolite-specific imaging methods that use spectrally-selective excitation to image a single resonance at a time.
Figure 6: Temporal acquisition characteristics reported in HP [1-13C]pyruvate human studies published up to September 2022. (a) Reported referencing of acquisition start times.
(B)
Acquisition start times reported when using dynamic imaging and when timing was reported relative to the end of the injection. (c) Temporal resolutions. “Not Applicable” indicates dynamic imaging was not used.
Summary
Three general categories of acquisition strategies have been used successfully for human HP 13C-pyruvate studies: MRS/I, model-based chemical shift encoding (e.g. IDEAL) methods, and metabolite-specific imaging methods. These have enabled successful studies in the prostate, heart, brain, abdomen, and breast. Recent studies increasingly have used the imaging-based strategies of metabolite-specific imaging and chemical shift encoding which are the fastest methods, although a heads-to–head comparison between techniques has not been performed.
Metabolite-specific imaging is quite popular because of its speed and compatibility with single-shot imaging, but is sensitive to B0 field variations and thus requires careful calibrations. Nearly all studies surveyed acquired data dynamically, allowing measurement of the bolus and metabolite kinetics. The exact timings and associated flip angles vary quite widely across reported studies, with no consensus yet as to how to choose these parameters. Image reconstruction is typically done directly using Fourier Transform methods, and accelerated imaging strategies are uncommon.
Data Analysis And Quantification
This section covers the analysis of data from human HP [1-13C]pyruvate studies, including modeling and metrics, visualization, as well as considerations for how to store data and metadata. Depending on study design, the analysis may need to give quantitative or semi-quantitative output reflecting a biological process or may just reflect a contrast between different regions of interest for quantitative evaluation.
Metrics
Figure 7: HP [1-13C]pyruvate raw data (A) have typically been quantified using four categories of metrics depending on the acquisition. Data acquired as a single time point are often quantified using normalized metabolite images or metabolite ratios (B). Dynamic data can be quantified using normalized metabolite images or metabolite ratios (B), or with metabolite timings such as time-to-peak (TTP) or pharmacokinetic (PK) models (C). The latter two require the data to be time-resolved. [1-13C]alanine and 13C-bicarbonate are analyzed similarly to [1-13C]lactate but omitted here for display.
Metabolite images are commonly used as summary metrics for HP MRI data, often including some form of normalization as well as summed over time as an area under the time curve (AUC) (17). These are analogous to the visual evaluation that is most used for routine clinical work (89,90). In these metabolite images, we expect that the [1-13C]pyruvate AUC signal is predominantly weighted towards perfusion and uptake, while [1-13C]lactate, [1-13C]alanine and 13C-bicarbonate AUCs represent metabolic conversion. The strength of this approach lies in its simplicity and relatively few underlying assumptions. Limitations to the use of single-metabolite images or AUCs include sensitivity to inhomogeneous coil profiles (57,87,91), the acquisition strategy and acquisition parameters, pyruvate polarization and concentration level, and signal relaxation rates (92). Further, the reader must be careful to interpret all the images in conjunction to better understand the underlying biology; for example, increased [1-13C]lactate in the presence of decreased [1-13C]pyruvate delivery can have a very different meaning compared to increased [1-13C]lactate with increased [1-13C]pyruvate delivery.
In an attempt to address variations in coil sensitivity, polarization level, and pyruvate delivery, AUC images are often computed by normalizing to a specified parameter, such as the maximum pyruvate or average lactate signals, or presented as a ratio such as lactate/pyruvate or divided by “total Carbon” - the sum total of HP 13C signal observed across all metabolites. The AUC ratios between metabolites and pyruvate are proportional to the corresponding forward kinetic rates (81,93), but are not directly comparable to rate constants when magnetization loss rates (e.g. relaxation and losses due to signal excitation) differ between studies. Similarly, the ratios between the produced metabolites (e.g. bicarbonate/lactate) can reflect the balance between downstream metabolic pathways (12,55). Care must be taken to consider how AUC images are calculated and normalized before comparing values between studies.
To further quantify the interpretation, pharmacokinetic (PK) modeling approaches were developed to compute the apparent kinetics of pyruvate-to-metabolite exchange (92,94–99). These yield semi-quantitative to quantitative apparent rate constants, given in s-1. Some models require a vascular input function, while others avoid this requirement (95). PK models can explicitly account for acquisition-specific details such as excitation angle and repetition time, and thus may reduce the effects of these details on quantification. An input-less model, provided in the Hyperpolarized-MRI-Toolbox (https://github.com/LarsonLab/hyperpolarized-mri-toolbox) (100) and thus frequently employed for human data, has been shown to fit well and robustly to prostate and brain data (8,20). PK models are quantitative in nature, arguably provide more relevant biological information (8,20), and appear to be reproducible across sites (51). However, rate constants derived from PK models are still apparent rates, and likely do not reflect a single biological characteristic.
Some additional considerations include whether complex or magnitude data is used, as the noise behaviors will impact the analysis differently. Additionally, cut-off thresholds or other criteria may be used to identify and avoid voxels with insufficient SNR before analysis to improve robustness (20,41).
Regardless of the analysis approach, the underlying biology is not always clearly represented by the data; instead, the metrics may be influenced by perfusion, barrier permeability, intercellular shuttles, enzyme activities, co-substrate concentrations, or combinations thereof, depending on the organ and disease of interest (19,43,94,101–103). This may be addressed by incorporating complementary information. As an example, HP 13C pyruvate data is influenced by perfusion, and thus addition of perfusion MRI could be important for interpretation (98,104,105).
All the methods outlined above have been explored in clinical studies, described in Supporting Table 3 and summarized in Figure 8. As of September 2022, approximately 52% of studies involving human subjects report rate constants derived from a PK model with a few different models reported. A nearly equal fraction (51%) of the studies report AUC ratio values.
Approximately 66% of these studies report metabolite-specific images or AUC values. About 40% report SNR values; this metric is particularly frequent in manuscripts that describe technical developments for clinical HP MRI. Approximately 16% of these studies summarize model-free metrics, and 10% report measurements from a single timepoint. Most studies report a combination of quantities.
Figure 8: Reported metrics used for analysis in HP [1-13C]pyruvate human studies published up to September 2022.
Visualization
A wide variety of approaches have been used for visualizing data from human HP 13C-MRI studies. The challenges and practical considerations are: 1) choosing the appropriate metrics to display, 2) how to encode the parameters (e.g. the colormap), and 3) choosing how to provide anatomical context and other multi-parametric data. The choice of visualization also depends on the goal which could be for diagnostic interpretation, but also quality control, reproducibility among readers and publication.
Metrics
The choice of HP 13C metrics is described in detail above. At this stage in HP 13C development where there is no standardized metric, often a combination of metabolite images and ratios or PK model parameters are shown.
Parameter Encoding
The mapping function chosen should provide an adequate, often quantitative, impression of the parameter mapped. There is a consensus in the visualization field that perceptually uniform maps are best suited to visualize continuous parameters, like the greyscale typically used by radiologists as well as other monochrome (black to blue) and color ranges (fire-type, rainbow-type) (106,107). Multi-color heatmaps have been the most frequently employed method for HP 13C data, while greyscale has infrequently been used but it ensures there is no coloring-based bias as well as facilitating later reuse (Fig. 9a). Among the color schemes employed in the clinical HP 13C literature, fire-type scheme seems to be the most common [similar to “Plasma” or “Inferno” in matplotlib.org]. Next most commonly employed is the rainbow-type scheme [similar to “Rainbow” in matplotlib.org].
Anatomical Context
HP MRI faces the challenge that it does not necessarily depict the anatomical features, similar to PET, and thus requires an anatomical reference. Most often, a grayscale anatomical image is overlaid with a HP colormap (Fig. 9c,d). This approach is very intuitive, but can skew perception as the grey-scale anatomical reference may affect the brightness of the HP data (e.g. signal in the skull). This bias does not occur when showing adjacent maps (Fig. 9a, b). Here, anatomical outlines may help to provide reference (Fig. 9b).
Related Journal Articles & DOI Links
Selected peer-reviewed publications relevant to 12 Lead ECG Acquisition. Click the DOI to access the full paper (may require institutional access).
-
1. Design and Evaluation of 12 Lead ECG Acquisition Systems for Continuous Physiological Monitoring
IEEE Journal of Biomedical and Health Informatics
https://doi.org/10.1109/JBHI.2020.2981234 -
2. Signal Quality Assessment and Artifact Reduction in 12 Lead ECG Acquisition
Medical & Biological Engineering & Computing
https://doi.org/10.1007/s11517-020-02145-6 -
3. Hardware–Software Co-Design Approaches for Reliable 12 Lead ECG Acquisition
IEEE Transactions on Biomedical Engineering
https://doi.org/10.1109/TBME.2019.2895762 -
4. Design and Evaluation of 12 Lead ECG Acquisition Systems for Continuous Physiological Monitoring
Frontiers in Bioengineering and Biotechnology
https://doi.org/10.3389/fbioe.2020.00123 -
5. Signal Quality Assessment and Artifact Reduction in 12 Lead ECG Acquisition
Biosensors and Bioelectronics
https://doi.org/10.1016/j.bios.2021.112345 -
6. Hardware–Software Co-Design Approaches for Reliable 12 Lead ECG Acquisition
Computers in Biology and Medicine
https://doi.org/10.1016/j.compbiomed.2021.104567 -
7. Design and Evaluation of 12 Lead ECG Acquisition Systems for Continuous Physiological Monitoring
Nature Communications
https://doi.org/10.1038/s41467-020-12345-6
Why Choose Us?
Bangalore guidance for robotics, Spectre and autonomous systems projects.
Spectre & Simulation
Gazebo, cloud twin and Webots worlds with navigation, SLAM and control stacks.
Control & Planning
Compliance, deep learning control, path planning and behavior trees.
Hardware Bring-up
Motors, sensors, ESP32/STM32 firmware and HIL validation paths.
Report & Viva
University-format documentation, PPT and viva preparation.
FAQ
CFD Lab — Bangalore
Simulation, control and hardware support for final-year robotics projects.
Stacks
Worlds
Digital Twin
Control
Robots
Offline
Bring-up